SEND SMS
SEND EMAIL

IVC Cage System

Individually Ventilated Caging System for Laboratory animals like mice and rat.

IVC Cage

IVC Cage
  • IVC Cage
  • IVC Cage
  • IVC Cage
Get Best Quote
Approx. Price: Rs 7,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity50 Piece
Usage/ApplicationIndividually ventilated cages for mice and rat
BrandORCHID
MaterialPlastic
CapacityMice and rat
ModelUS900
FeaturesIVC Cage for mice and rat
Automation TypeAutomatic
ColorYellow

Individually Ventilated Caging System: Technology built to protect animals and researchers

Orchid’s IVC system not only ensures high biological safety for laboratory animals and scientists, but also matches the at par level of compliance for safety, animal welfare and ergonomics.

 

Request
Callback


Additional Information:

  • Item Code: US900
  • Production Capacity: 1000
  • Delivery Time: 5-7weeks
  • Packaging Details: Box packing
Yes! I am interested

Animal Cage Changing Station

Animal Cage Changing Station
  • Animal Cage Changing Station
Ask For Price
Product Price :Get Latest Price

Product Details:

Minimum Order Quantity1 Set
Usage/ApplicationClinic Purpose
BrandOrchid Scientific
MaterialMS powder coated structure
Animal BreedLab Mice & Rat
DesignOrchid Scientific
ColorSilver
Cage SizeNA
Size CmNA

Animal Cage Changing Station

Animal Containment Workstations 

Animal cage changing and bedding disposal procedures are now simple and safe with the Orchid’s range of Animal Containment Workstations like Animal Cage Changing Station and Animal Bedding Disposal Unit.

Orchid’s Animal Cage Change Station gives the best allergen, microbial, and product protection, at lowest energy consumption and noise, while giving the ultimate user comfort. Orchid’s cage changing station has upstream and downstream dual air flow system which prevents hazardous allergens from escaping the work zone and external contaminated air from entering the work zone.

An animal cage change station is a clean bench designed specifically for procedures that could stir up allergens, such as animal cage changing. As room air is pulled in through the grills at the top side of cabinet, it passes through two filters – a pre-filter that captures large particles and then through a HEPA filter. The velocity with which HEPA filtered air travels from upside to downside on the workstation is measured and controlled through PLC. Similarly, the air above work surface is pulled through the grills on the work surface and then filtered through pre-filter and HEPA filter and then released in to the atmosphere. Air velocities in the range of 0.4 to 0.8m/s at both, upstream and downstream HEPA filters are controlled through PLC & monitored on touch screen display. Further, upper and lower limits for these velocities can be set so that if air velocity at any of the two positions is out of range then error signal in the form of indicator is shown.

Orchid’s Animal Cage Changing Station comes in variety of sizes and different optional features like Acrylic transparent shield, animal feed distribution funnel, UV Light, activated charcoal filter for usage in anaesthesia system etc.

Features

Easy to clean work surface and pre-filters

Touch screen display with data logging facility

Separate indicators for HEPA filter life & velocity out of range

Provision for electrical sockets and light facility

Dual side working

Durable and maintenance free

Ordering Information

Model No

Overall Dimensions Approx. (mm)

Details

Optional Accessories

Working voltage

 

CCS-01

 

 

 

1352 x 765 x 1922

 

 

Main work station with fluorescent light,

Castor wheels,

MS powder coated structure and S.S. 304 work top,

PLC control and Touch screen display with data logging

Acrylic shield on both side, UV light, Animal feed distribution funnel

 

 

220V Single phase, AC

Request
Callback


Additional Information:

  • Item Code: CCS-01
  • Production Capacity: 10 per Month
  • Delivery Time: 6 to 8 Weeks
  • Packaging Details: Corrugated Box Packing
Yes! I am interested

IVC System

IVC System
  • IVC System
  • IVC System
  • IVC System
Ask For Price
Product Price :Get Latest Price

Product Details:

Minimum Order Quantity01 Set
ModelRUS5S40
Usage/ApplicationIn laboratory animals,there is a huge demand for animals that have been kept in disease free
FeaturesContinuous monitoring of Temperature,Perct. RH,Ammonia and CO2 level and provision to set limits
Automation TypeSemi-Automatic
ColorSS
BrandOrchid Scientific
MaterialStainless Steel

Technology built to protect animals and researchers 

Orchid’s IVC system not only ensures high biological safety for laboratory animals and scientists, but also matches the at par level of compliance for safety, animal welfare and ergonomics.

 

Individually Ventilated Cage for Mice & Rat:

Ergonomics:

  • Safe quick and easy locking

  • Card holder fitting on the edge gives visibility of animal inside the cage

  • External self centering water bottle enabling quick bottle change without removing cage

  • Easily replacable breating filter

  • Excellent lid and tray stacking

Animal Welfare:

  • No direct air drift at animal level, air inlet and outlet at the top level ensures less animal stress and heat loss

  • 0.2µ Passive filter on cage lid ensuring animal safety in power failure or cage is off the rack for long time without compromising the protection

Safety:

Silicone compression seal in the lid ensuring complete seal around the cage

 

Air Handling Unit:

Ergonomics:

  • Light weight easy to move system with Touch screen display at eye level

  • Separate indicators on the control panel for indication of Parameters out of range, Supply HEPA filter change and exhaust HEPA filter change

  • Easy access to pre filters for routine cleaning

Animal Welfare:

  • Stand alone separate Air Handling Unit gives less vibrations and noise level to cage level

  • Continuous monitoring of Temperature, % RH and provision to set limits

  • Mobile messaging system for error logs enabling user to take immediate action to protect animals*

    (*Optional)

Economics:

  • Low power consumption and less maintenance blowers

  • Stand alone Air Supply Unit can connect to 4 racks

Compliance:

  • Two level password protected system ensuring restricted access

  • Auto data logging of parameters after every 2hrs

  • Error logs for parameters out of upper and lower limits set

 

Racks for Individually Ventilated Cages:

Orchid’s IVC Racking offers complete flexibility to meet any laboratory design. Fully mobile racks are available in wide range of cage capacities and in addition to that further racks can be added at any time to the existing Air Supply Unit.

 

 

 

 

 

 

 

 

 

 

 

 

Request
Callback


Additional Information:

  • Item Code: US500-US900
  • Production Capacity: 25 per Month
  • Delivery Time: 8 to 10 Weeks
  • Packaging Details: Corrugated Box Packing
Yes! I am interested

IVC Cage Mice

IVC Cage Mice
  • IVC Cage Mice
  • IVC Cage Mice
Ask For Price
Product Price :Get Latest Price

Product Details:

Minimum Order Quantity50 Piece
Usage/ApplicationIVC Cage
Capacity502 cm. sq.
ModelUS 500
Animal Breedmice rat
FeaturesPolysulfone cage
Automation TypeAutomatic
MaterialPlastic
BrandOrchid

Orchid’s IVC system not only ensures high biological safety for laboratory animals and scientists, but also matches the at par level of compliance for safety, animal welfare and ergonomics.

 

Ergonomics:

Safe quick and easy locking.

Card holder fitting on the edge gives visibility of animal inside the cage

External self centering water bottle enabling quick bottle change without removing cage

Easily replacable breating filter

Excellent lid and tray stacking 

 

Animal Welfare:

No direct air drift at animal level, air inlet and outlet at the top level ensures less animal stress and heat loss

0.2µ Passive filter on cage lid ensuring animal safety in power failure or cage is off the rack for long time without compromising the protection

 

Safety:

Silicone compression seal in the lid ensuring complete seal around the cage

Request
Callback


Additional Information:

  • Item Code: US500
  • Production Capacity: 1000pcs
  • Delivery Time: 8-10 weeks
  • Packaging Details: Box packing
Yes! I am interested
X

Explore more products



Reach Us
Parag Jain (Director)
B-59, M. I. D. C., Ambad
Nashik- 422010, Maharashtra, India



Call Us

Share Us

F GT L


Send E-mailSend SMS