SEND SMS
SEND EMAIL

IVC Cage System

Individually Ventilated Caging System for Laboratory animals like mice and rat.

IVC Cage mice

IVC Cage mice
  • IVC Cage mice
  • IVC Cage mice
Get Best Quote
Approx. Price: Rs 7,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity50 Piece
BrandOrchid
Animal Breedmice rat
MaterialPlastic
Automation TypeAutomatic
Capacity502 cm. sq.
ModelUS 500
FeaturesPolysulfone cage
Usage/ApplicationIVC Cage

Orchid’s IVC system not only ensures high biological safety for laboratory animals and scientists, but also matches the at par level of compliance for safety, animal welfare and ergonomics.

Ergonomics:

Quick finger touch swing type locks enabling quick locking and unlocking at the same time giving safe locking

Card holder fitting on the edge gives visibility of animal inside the cage

External self centering water bottle enabling quick bottle change without removing cage

Snap fit filter holder enabling easy removal of filter

Excellent lid stacking without damaging cage locks

Animal Welfare:

No direct air drift at animal level, air inlet and outlet at the top level ensures less animal stress and heat loss

0.2µ Passive filter on cage lid ensuring animal safety in power failure or cage is off the rack for long time without compromising the protection

 

Safety:

Air tight spring loaded air lnlet, air outlet and bottle inlet valves ensure no air leakage

Silicone compression seal in the lid ensuring complete seal around the cage

Request
Callback


Additional Information:

  • Item Code: US500
  • Production Capacity: 1000pcs
  • Delivery Time: 3-4weeks
  • Packaging Details: Box packing
Yes! I am interested
View PDF

IVC Cage

IVC Cage
  • IVC Cage
  • IVC Cage
Get Best Quote
Approx. Price: Rs 7,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity50 Piece
BrandORCHID
ModelUS900
MaterialPlastic
Automation TypeAutomatic
ColorYellow
FeaturesIVC Cage for mice and rat
Usage/ApplicationIndividually ventilated cages for mice and rat
CapacityMice and rat

Individually Ventilated Caging System: Technology built to protect animals and researchers

Orchid’s IVC system not only ensures high biological safety for laboratory animals and scientists, but also matches the at par level of compliance for safety, animal welfare and ergonomics.

 

Request
Callback


Additional Information:

  • Item Code: US900
  • Production Capacity: 1000
  • Delivery Time: 5-7weeks
  • Packaging Details: Box packing
Yes! I am interested
View PDF

IVC System

IVC System
  • IVC System
  • IVC System
  • IVC System
Ask For Price
Product Price :Get Latest Price

Product Details:

Minimum Order Quantity01 Set
ModelRUS5S40
Automation TypeSemi-Automatic
Usage/ApplicationIn laboratory animals,there is a huge demand for animals that have been kept in disease free
FeaturesContinuous monitoring of Temperature,Perct. RH,Ammonia and CO2 level and provision to set limits
BrandOrchid Scientific
ColorSS
MaterialStainless Steel

Technology built to protect animals and researchers

Orchid’s IVC system not only ensures high biological safety for laboratory animals and scientists, but also matches the at par level of compliance for safety, animal welfare and ergonomics.

 

Individually Ventilated Cage for Mice & Rat:

Ergonomics:

  • Quick finger touch swing type locks enabling quick locking and unlocking at the same time giving safe locking

  • Card holder fitting on the edge gives visibility of animal inside the cage

  • External self centering water bottle enabling quick bottle change without removing cage

  • Snap fit filter holder enabling easy removal of filter

  • Excellent lid stacking without damaging cage locks

Animal Welfare:

  • No direct air drift at animal level, air inlet and outlet at the top level ensures less animal stress and heat loss

  • 0.2µ Passive filter on cage lid ensuring animal safety in power failure or cage is off the rack for long time without compromising the protection

Safety:

Air tight spring loaded air lnlet, air outlet and bottle inlet valves ensure no air leakage

Silicone compression seal in the lid ensuring complete seal around the cage

 

Air Handling Unit:

Ergonomics:

  • Light weight easy to move system with Touch screen display at eye level

  • Separate indicators on the control panel for indication of Parameters out of range, Supply HEPA filter change and exhaust HEPA filter change

  • Easy access to pre filters for routine cleaning

Animal Welfare:

  • Stand alone separate Air Handling Unit gives less vibrations and noise level to cage level

  • Continuous monitoring of Temperature, % RH, Ammonia* and CO2 level* and provision to set limits

  • Emergency mode to protect the animals from higher level of Ammonia and CO2

  • Mobile messaging system for error logs enabling user to take immediate action to protect animals*

    (*Optional)

Economics:

  • Low power consumption and less maintenance blowers

  • Stand alone Air Supply Unit can connect to 4 racks

Compliance:

  • Two level password protected system ensuring restricted access

  • Auto data logging of parameters after every 2hrs

  • Error logs for parameters out of upper and lower limits set

 

Racks for Individually Ventilated Cages:

Orchid’s IVC Racking offers complete flexibility to meet any laboratory design. Fully mobile racks are available in wide range of cage capacities and in addition to that further racks can be added at any time to the existing Air Supply Unit.

  • Auto closing supply and exhaust rack valves improves the life of HEPA filters and reduce the accumulation of dust in the rack pipes (Patent Applied)
  • Cage holding rails fitted with visual docking indicators to ensuring proper fitting of cage

  • Spring loaded non rupture air supply and exhaust valve

  • Press fit air supply and exhaust valve allows easy removal for cleaning purpose

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Request
Callback


Additional Information:

  • Item Code: US500-US900
  • Production Capacity: 25 per Month
  • Delivery Time: 3 to 5 Weeks
  • Packaging Details: Corrugated Box Packing